Shizuoka University REpository  title image 
morning
day
evening
night
shizuppy
 

SURE: Shizuoka University REpository >
04. 理学部・理学研究科 = Faculty of Science >
静岡大学地球科学研究報告 (1975-) >
2002 29 >

このアイテムの引用には次の識別子を使用してください: http://doi.org/10.14945/00000384
Bookmark and Share

このアイテムのファイル:

ファイル 記述 サイズフォーマット
KJ00000102492.pdf1.75 MBAdobe PDFサムネイル
見る/開く

タイトル: GPSとラジオゾンデから推定される可降水量の相互比較
その他のタイトル: A comparison of precipitable water vapor obtained from GPS and radiosonde
著者: 西村, 昌明
内藤, 勲夫
岩淵, 哲也
里村, 幹夫
掲載誌名: 静岡大学地球科学研究報告
出版者: 静岡大学地球科学教室
巻: 29
開始ページ: 61
終了ページ: 75
出版日付: 2002-07
NDC: 451
抄録: In order to account for the validity of precipitable water vapor (PWV) obtained from Global Positioning System (GPS), we compared PWV obtained from GPS (GPS_PWV) and that obtained from radiosonde (SONDE PWV). We used radiosonde data from 14 stations in Japan, and also GPS data of GEONET stations established by Geographical Survey Institute (GSI) near radiosonde stations during January 1999 and December 2000 in the present investigation. The antenna phase center of GEONET. Varies by elevation angle of microwave path from GPS satellites, and we applied an antenna specific phase characteristic model to the GPS_PWV. When we estimated GPS_PWV without the antenna specific phase characteristic model, average difference between GPS_PWV and SONDE_PWV (GPS_PWV-SONDE_PWV : PWV difference) was -3.7mm. This average PWV difference varied by each antenna/monument type. On the other hand, when we estimated GPS_PWV with the antenna specific phase characteristic model, it decreased to 1.8mm. This PWV difference did not vary by antenna/ monument type. We also compared two kinds of PWV at 00UTC and those at 12UTC. At 12UTC, GPS_PWV was usually lower than SONDE_PWV when PWV increased. When it is rainy or very humid, GPS_PWV tended to be much lower than SONDE_PWV. This tendency was caused by the fact that the sensor of the , hygrometer of radiosonde was wet. Finally, we investigated a relationship between PWV difference and distance between ' GPS station and the position of radiosonde, but could not find a clear correlation between them.
ISSN: 03886298 OPAC
NII論文ID: 110000413416 ciniia
NII書誌ID: AN00103190 OPAC ciniib
バージョン: publisher
出現コレクション:2002 29

Google™ Scholar: Cited By - Related - Other Copies

Others By: 西村, 昌明 -- 内藤, 勲夫 -- 岩淵, 哲也 -- 里村, 幹夫 (サトムラ, ミキオ) (Satomura, Mikio)

本リポジトリに登録されているコンテンツの著作権は,執筆者,出版社、学協会などが有します。著作権者はコンテンツにより異なります。
本リポジトリに登録されているコンテンツの利用については,著作権法に規定されている私的使用や引用などの範囲内で行ってください。
著作権に規定されている私的使用や引用などの範囲を超える利用を行う場合には,著作権者の許諾を得てください。ただし,著作権者から著作権等管理事業者(学術著作権協会,日本著作出版権管理システムなど)に権利委託されているコンテンツの利用手続については,各著作権等管理事業者に確認してください。

 

Powered by DSpace Software Copyright © 2002-2007 MIT and Hewlett-Packard - ご意見をお寄せください